Triplex Service Drop
APPLICATION of tano cable Triplex Service Drop cable
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SPECIFICATION of tano cable Triplex Service Drop cable
Tano Cable's triplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).
• B-399 Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Tano Cable's triplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION of tano cable Triplex Service Drop cable
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
TECHNICAL DATA of tano cable Triplex Service Drop cable
| Code |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft.(lbs.) |
Allowable Ampacities |
| Size |
Stranding |
Insul. Thick. |
Equiv. Dia. |
Size |
Stranding |
Rated Strength |
XLP |
POLY |
XLP |
POLY |
| (AWG) |
(mils) |
(AWG) |
(kcmil) |
(lbs). |
| 6201 ALLOY NEUTRAL-MESSENGER |
| Minex |
6 |
1 |
45 |
6 |
30.58 |
7 |
1110 |
101 |
101 |
85 |
70 |
| Hippa |
6 |
7 |
45 |
6 |
30.58 |
7 |
1110 |
107 |
107 |
85 |
70 |
| Prawn |
4 |
1 |
45 |
4 |
48.69 |
7 |
1760 |
152 |
152 |
115 |
90 |
| Barnacle |
4 |
7 |
45 |
4 |
48.69 |
7 |
1760 |
160 |
160 |
115 |
90 |
| Shrimp |
2 |
7 |
45 |
2 |
77.47 |
7 |
2800 |
243 |
243 |
150 |
120 |
| Gammarus |
1/0 |
7 |
60 |
1/0 |
123.3 |
7 |
4460 |
390 |
390 |
205 |
160 |
| Leda |
1/0 |
9 |
60 |
1/0 |
123.3 |
7 |
4460 |
384 |
384 |
205 |
160 |
| Dungenese |
2/0 |
7 |
60 |
2/0 |
155.4 |
7 |
5390 |
483 |
483 |
235 |
185 |
| Cyclops |
2/0 |
11 |
60 |
2/0 |
155.4 |
7 |
5390 |
474 |
474 |
235 |
185 |
| Flustra |
3/0 |
17 |
60 |
3/0 |
195.7 |
7 |
6790 |
587 |
587 |
275 |
215 |
| Lepas |
4/0 |
18 |
60 |
4/0 |
246.9 |
7 |
8560 |
728 |
728 |
315 |
245 |
| *Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
| +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
| ++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
| Code |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft.(lbs.) |
Allowable Ampacities |
| Size |
Stranding |
Insul. Thick. |
Equiv. Dia. |
Size |
Stranding |
Rated Strength |
XLP |
POLY |
XLP |
POLY |
| (AWG) |
(mils) |
(AWG) |
(kcmil) |
(lbs). |
| 6201 ALLOY REDUCED NEUTRAL-MESSENGER |
| Artemia |
4 |
1 |
45 |
6 |
30.58 |
7 |
1110 |
135 |
135 |
115 |
90 |
| Crab |
4 |
7 |
45 |
6 |
30.58 |
7 |
1110 |
143 |
143 |
115 |
90 |
| Solaster |
2 |
7 |
45 |
4 |
48.69 |
7 |
1760 |
216 |
216 |
150 |
120 |
| Sandcrab |
1/0 |
7 |
60 |
2 |
77.47 |
7 |
2800 |
347 |
347 |
205 |
160 |
| Echinus |
1/0 |
9 |
60 |
2 |
77.47 |
7 |
2800 |
341 |
341 |
205 |
160 |
| Fulgar |
3/0 |
17 |
60 |
1/0 |
123.3 |
7 |
4460 |
519 |
519 |
275 |
215 |
| Arca |
4/0 |
18 |
60 |
2/0 |
155.4 |
7 |
5390 |
643 |
643 |
315 |
245 |
| *Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
| +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
| ++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
| Code |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft.(lbs.) |
Allowable Ampacities |
| Size |
Stranding |
Insul. Thick. |
Size |
Stranding |
Rated Strength |
XLP |
POLY |
XLP |
POLY |
| (AWG) |
(mils) |
(AWG or
kcmil) |
(lbs). |
| AAC NEUTRAL-MESSENGER |
| Patella |
6 |
7 |
45 |
6 |
7 |
563 |
103 |
103 |
85 |
70 |
| Oyster |
4 |
7 |
45 |
4 |
7 |
881 |
154 |
154 |
115 |
90 |
| Clam |
2 |
7 |
45 |
2 |
7 |
1350 |
233 |
233 |
150 |
120 |
| Murex |
1/0 |
7 |
60 |
1/0 |
7 |
1990 |
374 |
374 |
205 |
160 |
| Purpura |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
368 |
368 |
205 |
160 |
| Nassa |
2/0 |
7 |
60 |
2/0 |
7 |
2510 |
462 |
462 |
235 |
185 |
| Melita |
3/0 |
17 |
60 |
3/0 |
19 |
3310 |
562 |
562 |
275 |
215 |
| Portunus |
4/0 |
18 |
60 |
4/0 |
19 |
4020 |
696 |
696 |
315 |
245 |
| Nannynose |
336.4 |
19 |
80 |
336.4 |
19 |
6146 |
1118 |
1118 |
420 |
325 |
| * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
| + Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
| Code |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft.(lbs.) |
Allowable Ampacities |
| Size |
Stranding |
Insul. Thick. |
Size |
Stranding |
Rated Strength |
XLP |
POLY |
XLP |
POLY |
| (AWG) |
(mils) |
(AWG or
kcmil) |
(lbs). |
| ACSR NEUTRAL-MESSENGER |
| Paludina |
6 |
1 |
45 |
6 |
6/1 |
1190 |
109 |
109 |
85 |
70 |
| Voluta |
6 |
7 |
45 |
6 |
6/1 |
1190 |
114 |
114 |
85 |
70 |
| Whelk |
4 |
1 |
45 |
4 |
6/1 |
1860 |
-- |
164 |
115 |
90 |
| Periwinkle |
4 |
7 |
45 |
4 |
6/1 |
1860 |
172 |
172 |
115 |
90 |
| Conch |
2 |
7 |
45 |
2 |
6/1 |
2850 |
262 |
262 |
150 |
120 |
| Neritina |
1/0 |
7 |
60 |
1/0 |
6/1 |
4380 |
420 |
420 |
205 |
160 |
| Cenia |
1/0 |
9 |
60 |
1/0 |
6/1 |
4380 |
414 |
414 |
205 |
160 |
| Runcina |
2/0 |
7 |
60 |
2/0 |
6/1 |
5310 |
520 |
520 |
235 |
185 |
| Triton |
2/0 |
11 |
60 |
2/0 |
6/1 |
5310 |
512 |
512 |
235 |
185 |
| Mursia |
3/0 |
17 |
60 |
3/0 |
6/1 |
6620 |
635 |
635 |
275 |
215 |
| Zuzara |
4/0 |
18 |
60 |
4/0 |
6/1 |
8350 |
789 |
789 |
315 |
245 |
| Limpet |
336.4 |
19 |
80 |
336.4 |
18/1 |
8680 |
1167 |
1167 |
420 |
325 |
| *Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
| +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
| Code |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft.(lbs.) |
Allowable Ampacities |
| Size |
Stranding |
Insul. Thick. |
Size |
Stranding |
Rated Strength |
XLP |
POLY |
XLP |
POLY |
| (AWG) |
(mils) |
(AWG or
kcmil) |
(lbs). |
| ACSR REDUCED NEUTRAL-MESSENGER |
| Scallop |
4 |
1 |
45 |
6 |
6/1 |
1190 |
-- |
142 |
115 |
90 |
| Strombus |
4 |
7 |
45 |
6 |
6/1 |
1190 |
151 |
151 |
115 |
90 |
| Cockle |
2 |
7 |
45 |
4 |
6/1 |
1860 |
228 |
228 |
150 |
120 |
| Janthina |
1/0 |
7 |
60 |
2 |
6/1 |
2853 |
366 |
366 |
205 |
160 |
| Ranella |
1/0 |
9 |
60 |
2 |
6/1 |
2853 |
360 |
360 |
205 |
160 |
| Cavolinia |
2/0 |
7 |
60 |
1 |
6/1 |
3550 |
453 |
453 |
235 |
185 |
| Clio |
2/0 |
11 |
60 |
1 |
6/1 |
3550 |
444 |
444 |
235 |
185 |
| Aega |
3/0 |
17 |
60 |
1/0 |
6/1 |
4380 |
549 |
549 |
275 |
215 |
| Cerapus |
4/0 |
18 |
60 |
2/0 |
6/1 |
5310 |
681 |
681 |
315 |
245 |
| *Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
| +Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
get more information: http://www.tanocable.com/
skype:tanocable
Tel.:+86-371-60306197 +86-18937105488